Hyphenated interfaces for evolved gas analysis (EGA)  

Gain deeper insight into evaporation, decomposition, and other chemical reactions with evolved gas analysis (EGA). 
REDshift hyphenation helps you uncover the origins of complex samples by using your preferred TGA, FT-IR and GC/MS instruments.

REDshift Hyphenation Systems

Achieve Great Identification from a Single Run

Start the quantification process of a small sample, using either a controlled thermal ramp or a defined isothermal setting. 
Track gaseous evolution for each weight-loss step, without dilution or saturation effects.

TG-IRe Interface

tg-ir interface from redshift, between tga and ftir instruments
Performs real-time analysis, providing valuable information on the composition of evolved gases generated in you thermal analyzer.
Ensures easy data interpretation and minimal system maintenance on your interface, TGA and FT-IR instruments.
- Heated transfer line  
- Heated Zero Gravity IR cell 
- Adapter specifically designed for your TGA 
- E-controller Kit 

TG-GCMSe Interface

Evolved gases are trapped in a heated sampling loop contained and injected in the GC-MS. Perform GC separation and MS analysis to targeted chromatogram information. 
The interface design is also capable of skipping GC separation to MS online analysis, by using its single-ion mode capability.
- Heated transfer line  
- Heated GCMS injection block 
- Adapter specifically designed for your TGA 
- E-controller kit

TG-IR-GCMSe Interface

tg-ir-gcms interface for hyphenation between tga, ft-ir and gcms instruments
Designed for a deep understanding of processes inside the thermal analyzer. 
Characterize unknown elements with confidence. The system sequentially directs evolved gases from the thermo-gravimetrical analyzer to the FT-IR and then to the GC-MS instruments. During thermal separation, the FT-IR provides real-time spectral sequences, while the GC-MS enables separation and precise peak identification. MS online by skipping GC is also possible.
- Heated transfer lines
- Heated Zero Gravity IR cell
- Heated GCMS injection block
- Adapter specifically designed for your TGA
- E-controller kit

TG-MSe Interface

tg-ms interface for hyphenation between tga and ms instruments
Targets real-time of lowest levels of known elements in complex mixtures. The mass spectrometer (MS) is isolated during stand-by and TGA sample loading, preventing ambient air contamination. Evolved gases are introduced only when an event is detected during the TGA run.
- Heated transfer line
- Heated MS injection block
- Adapter specifically designed for your TGA
- E-controller kit

Want to know more?

Download the brochure, or contact us to speak directly with our experts...

Advantages of using different techniques combined together

CONTINUOUSLY HEATED
devices.
ADJUSTABLE AND PROGRAMMABLE
temperatures.
COSTUMIZABLE FLOW RATE
for precise control.
GREAT INTEGRATION
with third-party instrument.
TGA ADAPTER
designed for your thermal analyzer.
DEAD VOLUME MINIMIZATION
and clogging prevention.
SPECIALIZED IR GAS CELL
for evolved gases.
MULTIPLE INJECTIONS CAPABILITY
for a single TGA run.

Applications across industries

Chemicals and polymers identification
Material decomposition
Solvent and contaminants detection
Petrochemical products
Residual solvents
Environmental and food pollutants
Microplastics research
Renewable energy and batteries
Semiconductors
Outgassing properties
Nanotechnologies research
New products development
Reverse engineering
Identification of unknown elements
Enhanced Features,
Superior Performances!
Controlled temperatures & flows
Settables with stable & constant gas speed.
We made evolved gas analysis simpler and automated, with high sensitivity and exceptional baseline stability. This ensures repeatable qualitative and quantitative analysis for your sample. The interface is ready-to-use and provides easy control over all parameters!

Stand-by mode

Reduce the temperature of heated zones when the system is not in use.

Automatic pump shutdown

Set up pump temperature and timing to preserve the system quality.

Main menu

Contains further functions such as: option1, option2, option3...

Temperatures check

Easy adjustable heating zones.

Flow check

Control gas flow through the path.

Want to know more?

Download the brochure, or contact us to speak directly with our experts...
Additional features!
Temperature ramp
Set up a temperature ramp to reduce the risk of secondary pyrolysis caused by high temperatures in the hyphenation system. Prevents the destruction of elements during your analysis.
CLIMACHROM2000
Perform gas chromatography up to -20°C. Drastically reduces high acquisitions costs from disposable gases, reaching higher performances.
Learn more about Climachrom2000.
GC multiple injection
Allows multiple GC injections during a single TGA run using fast cooling capability or shorter columns technique. Our proprietary design prevents gas stagnation and clogging from analyte deposition after several runs.
Web server mode
The controller is equipped with a touchscreen panel and intuitive software. Save space: the screen can be accessed from your computer with a common browser, leaving the controller under the table.